View count:
6348
Mass Spectrometry Core
SCIEX API2000 LC-MS/MS
Applications
- Trace analysis in: Environmental samples,Pharmaceutical analyses,Biological samples
- Structure confirmation analyses
- Updating existing methodology for higher specificity or sensitivity
- Instrument:API 2000™ System
- Ion Source:ESI
- HPLC:Agilent 1260 Infinity Quaternary LC System
- Software:Analyst® Software
Technician:
Liu, Chun-Chih jared0930@tmu.edu.tw Tel:2687(Xinyi)
Information


Agilent 6470 LC-MS/MS
Applications
- Trace analysis in: Environmental samples,Pharmaceutical analyses,Biological samples
- Structure confirmation analyses
- Updating existing methodology for higher specificity or sensitivity
- Instrument:Agilent 6470
- Ion Source:ESI
- HPLC:Agilent 1290 Infinity II LC System
- Software:Agilent MassHunter Workstation® Software
Technician:
Liu, Chun-Chih jared0930@tmu.edu.tw Tel:2687(Xinyi)
Information
Waters TQXS LC-MS/MS
Applications
- Trace analysis in: Environmental samples,Pharmaceutical analyses,Biological samples
- Structure confirmation analyses
- Updating existing methodology for higher specificity or sensitivity
- Instrument:Waters Xevo TQ-XS
- Ion Source:ESI、UniSpray™、APGC
- HPLC:ACQUITY UPLC、Agilent 7890 GC
- Software:Waters Masslynx、Targetlynx
Technician:
Chuang, Yung-Ning a0194128@tmu.edu.tw Tel:2705(Xinyi)
Information


Thermo X-2 ICP-MS
Applications
- Measuring trace inorganic elements.
- Instrument::Thermo X Series II
- Ion Source:Plasma
- Automatic Sampler:CETAC ASX-520
- Automatic diluter:Thermo ID 100
- Chiller:Thermo MERLIN M75
- HPLC:
- Degasser: ERC-3415
- Pump: P4000
- Autosampler: AS3500
-
Location: Mass Core Room, B1F, Health Science Building
Technician:
Liu, Chun-Chih jared0930@tmu.edu.tw Tel:2687(Xinyi)
Information
Agilent 8900 ICP-MS/MS
Applications
- Measuring trace inorganic elements.
- Inorganic Species
- Nanoparticles Analysis
- Single Cell Analysis
- Instrument:Agilent 8900 ICP-MS/MS
- Ion Source:Plasma
- Automatic Sampler:SPS4,ISIS3
- HPLC:Agilent 1260 Infinity Quaternary LC System
Technician:
Liu, Chun-Chih jared0930@tmu.edu.tw Tel:2687(Xinyi)
Information


Agilent 5977 GC-MSD
Applications
- Flavours, volatile organic compounds Analyst
- Instrument:Agilent 5977 GC-MSD
- Ion Source:EI
- Gas Chromatography:Agilent 7820A GC System
- Database:NIST、Wiley
Technician:
Chuang, Yung-Ning a0194128@tmu.edu.tw Tel:2705(Xinyi)
Information
Time-of-Flight Secondary Ion Mass Spectrometer(ToFSIMS)
Applications
- Mass Spectrometry Imaging
- Depth Profile
- Three-Dimensional Analyst
- Instrument:ULVAC-PHI TRIFT IV
- Ion Gun:
- Ultra High Vacuum System
- WinCadence4.7 Software
Technician:
Clement Lee januslee@tmu.edu.tw Tel:2632(Xinyi)
Information


Quadrupole Time-of-Flight Mass Spectrometry(Q-ToF)
Applications
- Qualitative Quantification of Large and Small Molecules
- Protein Identification
- Metabolomics Research
- MS Image Analysis of Tissue Substrate Targets
- Instrument:Waters SYNAPT G2 8K
- Ion Source:ESI、nanoESI、MALDI
- HPLC:ACQUITY UPLC、nanoACQUITY UPLC
- Software:ProteinLynx Global SERVER、MetaboLynx XS、ChromaLynx、MassFragment、BiopharmaLynx、MarkerLynx XS、MaxEnt
Technician:
Chuang, Yung-Ning a0194128@tmu.edu.tw Tel:2705(Xinyi)
Information